Uni-Trend UT201 Spezifikationen

Stöbern Sie online oder laden Sie Spezifikationen nach Multimeter Uni-Trend UT201 herunter. Uni-Trend UT201 multimeter Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 32
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
1
Model UT201/202: OPERATING MANUAL
Table of Contents
Title Page
Overview
Unpacking Inspection
Safety Information
Rules For Safe Operation
International Electrical Symbols
The Meter Structure
Rotary Switch
Functional Buttons
The Effectiveness of Functional Buttons
Display Symbols
Measurement Operation
A. DC Voltage Measurement
B. AC Voltage Measurement
C. Measuring Resistance
D. Testing Diodes
E. Testing for Continuity
F. Temperature Measurement
G. AC Current Measurement
Sleep Mode
Specifications
A. General Specifications
B. Environmental Restriction
Accuracy Specifications
A. AC Voltage
B. DC Voltage
C. Resistance
D. Continuity Test
E. Diode Test
F. Temperature
G. AC Current
Maintenance
A. General Service
B. Replacing the Battery
3
4
5
6
8
9
10
11
12
13
15
15
16
17
19
20
22
23
25
26
26
26
27
27
27
28
28
28
29
29
30
30
30
Seitenansicht 0
1 2 3 4 5 6 ... 31 32

Inhaltsverzeichnis

Seite 1

1Model UT201/202: OPERATING MANUALTable of ContentsTitle PageOverviewUnpacking

Seite 2

Rotary SwitchBelow table indicated for information about the rotary switchpositions.RotarySwitchPositionFunctionAC/DC voltage measurement.: Diode test

Seite 3

Functional Buttons(1)Below table indicated for information about the functionalbutton operations.AC voltage measurement.l Press HOLD

Seite 4 - Unpacking Inspection

The Effectiveness of Functional ButtonsNot every functional buttons can be used on every rotaryswitch positions. Below two tables describe which func

Seite 5

Display Symbols(1) (see figure 2)No. Symbol Meaning3The battery is low. Warning: To avoid false readings,which could lead to

Seite 6

No. Symbol Meaning 11 A Amperes (amps). The unit of current.Display Symbols(2) (see figure 2)mV, V Volts

Seite 7 - Rules For Safe Operation (2)

Measurement Operation(1)WarningTo avoid harms to you or damages to the Meter fromeletric shock, do not attempt to measure voltageshigher than 600V AC/

Seite 8

Measurement Operation(2)l When DC voltage measurement has been completed, disconnect the connection between the testing leads and the circui

Seite 9 - ( figure 1)

Measurement Operation(3)Notel In each range, the Meter has an input impedance of 10MΩ. This loading effect can cause measurement errors in h

Seite 10 - Rotary Switch

Measurement Operation(4)The resistance ranges are:200.0, 2.000k , 20.00k ,200k ,2.000M and 20.00M .To measure resistance, connect the Meter as follow

Seite 11 - Functional Buttons(1)

Measurement Operation(5)D.Testing Diodes (see figure 6) red black( figure 6)WarningTo avoid damages to the Meter or to the devices undertest, dis

Seite 12 - (K-Type)

Table of ContentsTitle PageOverviewUnpacking InspectionSafety InformationRules F

Seite 13 - (see figure 2)

Measurement Operation(6)Notel In a circuit, a good diode should still produce a forward voltage drop reading of 0.5V to 0.8; however, the

Seite 14

Measurement Operation(7)WarningTo avoid damages to the Meter or to the devices undertest, disconnect circuit power and discharge all thehigh-voltage c

Seite 15 - Measurement Operation(1)

Measurement Operation(8)F. Temperature Measurement (UT202 Only) (see figure 8)The temperature measurement ranges are -40oC~1000oCand -40oF~1832oF

Seite 16 - Measurement Operation(2)

Measurement Operation(9)G. AC Current Measurement (see figure 9)( figure 9)WarningTo avoid electric shock, never measure current whilethe test leads

Seite 17 - Measurement Operation(3)

Measurement Operation(10)Note:l To obtain accurate reading, measure only one conductor at each time.l When current measurement has been complete

Seite 18 - Measurement Operation(4)

25To preserve battery life, the Meter automatically turnsoff if you do not turn the rotary switch or press any buttonfor around 15 minutes.The Meter c

Seite 19 - Measurement Operation(5)

SpecificationsA.General Specifications:l Maximum voltage including transient overvoltage between any terminals and grounding: 500V rms.l Display:

Seite 20 - Measurement Operation(6)

Accuracy: (a% reading + b digits), guarantee for 1 year.Operating temperature: 23oC 5oCRelative humidity: 75%R.HTemperature coefficient: 0.1x(speci

Seite 21 - Measurement Operation(7)

Accurate Specifications(2)C. Resistance: Auto ranging200.0Ω2.000kΩ20.00kΩ200.0kΩ2.000MΩ20.00MΩRange Resolution(1%+2)OverloadProtectionAccuracy(1.2%+2)

Seite 22 - Measurement Operation(8)

Accurate Specifications(3)F. Temperature (UT202 Only):Range ResolutionOverloadProtectionAccuracy-40~1000oC-40oF~1832oF1oC1oF-40~0oC:(3%+4)0~400oC:(1%+

Seite 23 - Measurement Operation(9)

OverviewThis Operating Manual covers information on safetyand cautions. Please read the relevant informationcarefully and observe all the Warnings and

Seite 24 - Measurement Operation(10)

MAINTENANCE(1)This section provides basic maintenance informationincluding battery replacement instruction.WarningDo not attempt to repair or service

Seite 25 - Sleep Mode

MAINTENANCE(2)WarningTo avoid false readings, which could lead to possibleelectric shock or personal injury, replace the batteryas soon as the battery

Seite 26 - Specifications

Copyright 2001 Uni-Trend Group Limited.All rights reserved.Manufacturer:Uni-Trend Technology (Dongguan) LimitedDong Fang Da DaoBei Shan Dong Fang Indu

Seite 27 - Accurate Specifications(1)

In the event you find any missing or damage, pleasecontact your dealer immediately.Unpacking InspectionOpen the package case and take out the Meter. C

Seite 28 - Accurate Specifications(2)

Safety InformationThis Meter complies with the standards IEC61010: inpollution degree 2, overvoltage category (CAT. II 600V,CAT. III 300V) and double

Seite 29 - Accurate Specifications(3)

Rules For Safe Operation (1)l Before using the Meter inspect the case. Do not use the Meter if it is damaged or the case (or part of the ca

Seite 30 - MAINTENANCE(1)

Rules For Safe Operation (2)l When the Meter working at an effective voltage over 60V in DC or 30V rms in AC, special care should be taken

Seite 31 - MAINTENANCE(2)

International Electrical SymbolsAC (Alternating Current).DC (Direct Current).AC or DC.Grounding.Double Insulated.Continuity Test.Diode.Fuse.Warning.

Seite 32

9The Meter Structure (see figure 1)( figure 1)1. Input Terminals2. LCD Display3. Functional Buttons4. Rotary Switch5. Trigger: press t

Kommentare zu diesen Handbüchern

Keine Kommentare