Model UT602/603: OPERATING MANUAL
Table of Contents
Title Page
Overview
Unpacking Inspection
Safety Information
Rules For Safe Operation
International Electrical Symbols
The Meter Structure
Functional Buttons
Display Symbols
Measurement Operation
A. Measuring Resistance
B. Diode and Continuity Test
C. Capacitance Measurement
D. Inductance Measurement
E. Transistor hFE Measurement
General Specifications
Accuracy Specifications
A. Resistance Test
B. Continuity & Diodes
C. Capacitance Test
D. Inductance Test
E. Transistor
Maintenance
A. General Service
B. Replacing the Battery
C. Replacing the Fuse
3
4
4
5
7
8
9
10
11
11
13
15
17
18
19
20
20
21
21
22
22
23
23
24
25
Seitenansicht 0
1 2 3 4 5 6 ... 25 26

Inhaltsverzeichnis

Seite 1

1Model UT602/603: OPERATING MANUALTable of ContentsTitle PageOverviewUnpacking InspectionSafety InformationRules

Seite 2

β10Model UT602/603: OPERATING MANUALDisplay Symbols (see figure 2)(figure 2)Data hold is active.The battery is low. Warning: To avoid false read

Seite 3 - Overview

Make sure the Low Battery Display is not on,otherwise false readings may be provided.Pay extra attention to the symbol, before carryingme

Seite 4 - Safety Information

When measuring at 20 and 200 range, the test clipscan add 0.1 to 0.3 error to resistance. To obtain precisereadings in these low-resistance measur

Seite 5 - Rules For Safe Operation

To avoid damages to the Meter or to the devices undertest, disconnect circuit power and discharge all thehigh-voltage capacitors before measuring diod

Seite 6

In a circuit, a good diode should still produce a forwardvoltage drop reading of 500mV to 800mV; however, thereverse voltage drop reading can vary dep

Seite 7

To avoid damage to the Meter or to the equipmentunder test, disconnect circuit power and discharge allhigh-voltage capacitors before measuring capacit

Seite 8

To minimize the effect of capacitance stored in the testclips, the test clips should be as short as possible anduse the small value jack when measurin

Seite 9 - Functional Buttons

To test the inductance, please follow the following procedure:Set the rotary switch to Lx measurement mode.If the tested inductance value is unknown,

Seite 10

To measure transistor, set up the Meter as follows:Set the rotary switch to hFE measurement mode.Check that the transistor is PNP or NPN type.Insert t

Seite 11 - Measurement Operation

Fused Protection for Inductance Input Terminal (UT602):0.315A, 250V, fast type fuse, 5x20 mm.Fuse Protection for Inductance and capacitance InputTerm

Seite 12

2Model UT602/603: OPERATING MANUAL

Seite 13

Overload protection: 250V DC or AC rms at all ranges.At 20M range, short circuit test lead, LCD displaying12 digits is normal. During measurement mi

Seite 14

Diode:Open Circuit Voltage around 5.8V, forward current around1mA.Continuity 10 , beeper comes on continuously.> 10 , beeper may or may not comes o

Seite 15

Measure of Inductance: 1H=103mH = 106µΗ.Overload Protection:0.315A, 250V, fast type fuse, 5x20 mmllThe display value is thetested transistor’s(NPN, P

Seite 16

This section provides basic maintenance informationincluding battery and fuse replacement instruction.Do not attempt to repair or service your Meter u

Seite 17

To avoid false readings, which could lead to possibleelectric shock or personal injury, replace the batteryas soon as the battery indicator “ ” app

Seite 18

To avoid electrical shock or arc blast, or personalinjury or damage to the Meter, use specified fusesONLY in accordance with the following procedure.W

Seite 19 - General Specifications

Copyright 2005 Uni-Trend Group Limited.All rights reserved.Manufacturer:Uni-Trend Technology (Dongguan) LimitedDong Fang Da DaoBei Shan Dong Fang Indu

Seite 20 - Accuracy Specifications

To avoid electric shock or personal injury, read the“Safety Information” and “Rules for Safety Operation”carefully before using the Meter.Warning3Mode

Seite 21 - B. Continuity & Diodes

4Model UT602/603: OPERATING MANUALUnpacking InspectionOpen the package case and take out the Meter. Checkthe following items carefully to see any mis

Seite 22 - E. Transistor

To avoid possible electric shock or personal injury,and to avoid possible damage to the Meter or to theequipment under test, adhere to the following r

Seite 23 - Maintenance

Remove test clips from the Meter and turn the Meterpower off before opening the Meter case.When servicing the Meter, use only the same modelnumber or

Seite 24

Lx7Model UT602/603: OPERATING MANUALInternational Electrical SymbolsGroundingDouble InsulatedDeficiency of Built-In Battery.Continuity Test.Diode.Capa

Seite 25

8Model UT602/603: OPERATING MANUALThe Meter Structure (see figure 1)1. LCD Display2. Data Hold (UT602) or L-C switch (UT603)3. Transistor Jack4. Resis

Seite 26

PowerHold(UT602only)L-C(UT603only)9Model UT602/603: OPERATING MANUALFunctional ButtonsBelow table indicated for information about the functionalbutton