Uni-Trend UT39A Spezifikationen

Stöbern Sie online oder laden Sie Spezifikationen nach Multimeter Uni-Trend UT39A herunter. Uni-Trend UT39A multimeter Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 28
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
TABLE OF CONTENTS
TITLE PAGE
Overview
Unpacking Inspection
Safety Information
Rules For Safe Operation
International Electrical Symbols
The Meter Structure
Functional Buttons
Display Symbols
Measurement Operation
A. DC Voltage Measurement
B. AC Voltage Measurement
C. DC Current Measurement
D. AC Current Measurement
E. Measuring Resistance
F. Frequency Measurement (The Model UT39C only)
G. Temperature Measurement (The Model UT39C only)
H. Capacitance Measurement
I. Measuring Diodes & Continuity
J. Measuring Transistor
Sleep Mode
General Specifications
Accuracy Specifications
A. DC Voltage
B. AC Voltage
C. DC Current
D. AC Current
E. Resistance Test
F. Frequency (The Model UT39C only)
G. Temperature (The Model UT39C only)
H. Capacitance
1
3
3
4
5
7
7
8
8
9
9
10
11
13
14
15
16
17
18
19
20
20
21
21
21
22
22
23
23
23
24
Model UT39A/B/C: OPERATING MANUAL
Seitenansicht 0
1 2 3 4 5 6 ... 27 28

Inhaltsverzeichnis

Seite 1

TABLE OF CONTENTSTITLE PAGEOverviewUnpacking InspectionSafety InformationRules For Safe OperationInternational Electrical Symbo

Seite 2

Note If the value of voltage to be measured is unknown, use the maximum measurement position (1000V) and reduce the range step by step until

Seite 3 - Unpacking Inspection

11NotellllIf the value of voltage to be measured is unknown,use the maximum measurement position (750V) andreduce the range step by step until a sat

Seite 4 - Safety Information

4. Break the current path to be tested. Connect the red test lead to the more positive side of the break and the black test lead to the more neg

Seite 5 - Rules For Safe Operation

D. AC Current Measurement (see figure 4 with dotted line) WarningNever attempt an in-circuit current measurementwhere the voltage between termina

Seite 6

E. Measuring Resistance (see figure 5) WarningTo avoid damages to the Meter or to the devicesunder test, disconnect circuit power and dischargeal

Seite 7 - ( figure 1)

F. The Model UT39C: Frequency Measurement (see figure 6) WarningTo avoid harm to you or damages to the Meter, donot attempt to measure voltage

Seite 8 - ( figure 2)

G. The Model UT39C: Temperature Measurement (see figure 7) WarningTo avoid harm to you or damages to the Meter, donot attempt to measure vol

Seite 9 - Measurement Operation

17H. Capacitance Measurement (see figure 8)( figure 8) WarningTo avoid damage to the Meter or to the equipmentunder test, disconnect the tested

Seite 10

I. Measuring Diodes & Continuity WarningTo avoid damage to the Meter or to the equipmentunder test, disconnect circuit power and dischargeall

Seite 11 - Black Red

19Testing for ContinuityTo test for continuity, connect the Meter as below:1. Insert the red test lead into VΩ terminal and the black test lead i

Seite 12

242425252526 PAGE I. Diodes and Continuity Test J. Transistor TestMaintenance A. General Service B. Replacing the

Seite 13

NoteWhen transistor measeurement has been completed,remove the transistor from the transistor jack.lSleep ModeTo preserve battery life, the Meter auto

Seite 14 - ( figure 5)

Accuracy SpecificationsAccuracy: (a% reading + b digits), guarantee for 1 year.Operating temperature: 230C 50C.Relative humidity: <75%.Temperatu

Seite 15 - (figure 6)

C. DC CurrentRange Resolution(2%+5)OverloadProtection0.315A. 250Vfast type fuse, φ 5 x 20mmUn-FusedAccuracyUT39A UT39B UT39C20µA200µA2mA20mA200mA10A/2

Seite 16 - (see figure 7)

E. Resistance TestRange Resolution(0.8%+3)OverloadProtection250V DCor AC rmsAccuracyUT39A UT39B UT39C200Ω2kΩ20kΩ200kΩ2MΩ20MΩ200MΩ0.1Ω1Ω10Ω100Ω1kΩ10kΩ1

Seite 17

H. CapacitanceRange Resolution(4%+3)OverloadProtection250V ACAccuracyUT39A UT39B UT39C1pF0.1nF1nF10nF(4%+3)(4%+3)Remark:Testing signal: approx. 400Hz

Seite 18

25MaintenanceThis section provides basic maintenance informationincluding battery and fuse replacement instruction. WarningDo not attempt to rep

Seite 19

To replace battery:1. Disconnect the connection between the testing leads and the circuit under test, and remove the testing leads away from the

Seite 20 - General Specifications

276. Remove the fuse by gently prying one end loose, and then take out the fuse from its bracket.7. Install ONLY replacement fuses with the identi

Seite 21 - Accuracy Specifications

Copyright 2004 Uni-Trend Group Limited.All rights reserved.Manufacturer:Uni-Trend Technology (Dongguan) LimitedDong Fang Da DaoBei Shan Dong Fang Indu

Seite 22 - (0.8%+1)

3Overview WarningTo avoid electric shock or personal injury, read the“Safety Information” and “Rules for Safety Operation”carefully before usi

Seite 23 - [5%(reading-10)+10]

Safety InformationThis Meter complies with the standards IEC61010: inpollution degree 2, overvoltage category (CAT. I 1000V,CAT. II 600V) and double i

Seite 24

Rules For Safe Operation WarningTo avoid possible electric shock or personal injury,and to avoid possible damage to the Meter or to theequipment

Seite 25 - Maintenance

lllllllllcontinuity, diodes, capacitance or current.Before measuring current, check the Meter’s fusesand turn off power to the circuit before connecti

Seite 26

Deficiency of Built-In BatteryAC (Alternating Current)AC or DCDouble InsulatedWarning. Refer to the Operating ManualConforms to Standards of European

Seite 27

ButtonPOWER(Yellow Button)HOLD(Blue Button)Operation PerformedTurn the Meter on and off. Press down the POWER to turn on the Meter. Press up the

Seite 28

9Make sure the Sleep Mode is not on if you found thereis no display on the LCD after turning on the Meter.Make sure the Low Battery Display i

Kommentare zu diesen Handbüchern

Keine Kommentare